ChromoSphere-T Certified Size Standards

ChromoSphere-T Certified Size Standards are designed for use as reference or calibration materials in applications where high contrast is required. To accomplish this, our polymer particles are deeply and internally dyed with intense red or black colors that standout and are highly visible against most background materials. The diameters are also traceable to the Standard Meter of the National Institute of Standards and Technology (NIST) and are calibrated by optical microscopy. They are available in a wide range of uniform, NIST traceable nominal diameter sizes from 50 μm up to 500 μm.

part no nominal diameter quantity count per gram color size distribution
RD050T   50μm 1g 1.5 x 107 Red σ = 3.8µm, 7.7% CV
RD100T 100μm 1g 11.8 x 106 Red σ = 7.5µm, 7.8% CV
RD150T 150μm 1g 5.4 x 105 Red σ = 9.0µm, 6.0% CV
RD200T 200μm 1g 2.3 x 105 Red σ = 9.5µm, 4.7% CV
RD300T 300μm 1g 6.6 x 104 Red σ = 11µm, 3.5% CV
RD400T 400μm 1g 2.8 x 104 Red σ = 18 µm, 4.4% CV
RD500T 500μm 1g 1.4 x 104 Red σ = 24µm, 4.8% CV
BK050T   50μm 1g 1.5 x 107 Black σ = 3.8µm, 7.7% CV
BK100T 100μm 1g 1.8 x 106 Black σ = 7.5µm, 7.8% CV
BK150T 150μm 1g 5.4 x 105 Black σ = 9.0µm, 6.0% CV
BK200T 200μm 1g 2.3 x 105 Black σ = 9.5µm, 4.7% CV
BK300T 300μm 1g 6.6 x 104 Black σ = 11µm, 3.5% CV
BK400T 400μm 1g 2.8 x 104 Black σ = 18 µm, 4.4% CV
BK500T 500μm 1g 1.4 x 104 Black σ = 24µm, 4.8% CV

Composition: Polystyrene Divinylbenzene (PS-DVB)
Density Particle: 1.05g/cm3
Size[s]: 1 gram
Stability: Product stable for a minimum of 24 months
Additive: None
Includes: Material Safety Data Sheet (MSDS), Certificate of Calibration and Traceability to NIST
Storage Requirements Store at room temperature. Keep bottle tightly sealed to avoid contamination.

Handling: ChromoSphere-T Size Standards are made from cross-linked polystyrene divinylbenzene (PS-DVB) copolymer that needs to be stored at room temperature. They can be dispersed in aqueous media with the aid of a small amount of surfactant or in lower alcohols such as methanol or ethanol. Some dye extraction will occur when the particles are suspended in pure alcohols, but it will be minimal. Other organic solvents, such as ethers or chlorinated hydrocarbons, should be avoided because they will swell the particles and completely extract the dye. 

Recommended for applications requiring monodisperse inorganic spheres like glass, silica which has a much higher density than polystyrene and the opaque spheres provide more contrast than polymer particles in optical and electron beams. Chromospheres are calibrated and certified with NIST traceable mean diameters and are suitable for a wide variety of particle measurement
application:
filter-testing
sieving-analysis

MSDS